Mechanical parts:
1,electronic platform scales the gap to a foreign body may not be around jammed,activity freely,such as a foreign body must be stuck clean.
2,often cleaning the scale body mesa,maintain clean (built devices:the annual scale body surface paint).
3,fittings once every six months to maintain,supporting the head after cleaning daub butter.
4,electronic scales are strictly prohibited to on the welding work or will scale Taiwan as a ground use.
5,sensors and balance of a limit clearance for 2 ~ 3 mm,such as the gap is not suitable to adjust.
6,the foundation pit should not water,by heavy rain causes such as foundation pit water,should be removed immediately with water pump or dredge drainage channel,and take measures to dry after be electricity meter.
7,weighing vehicles must not be more than 5 km top speed /, banning cars in a violent scale above the emergency brake.
8,weigh weight and goods total vehicle weight should not be more than the rated weighed.
What should Electronic platform balance worker to do?
1,a visual check scale (every day).
2,limit adjustment (quarter).
3,unloading bolt clearance check (half a year).
4,fitting location checks (half a year).
5,junction box sealing and connection check (years).
6,is likely to affect the normal work of the components of the instruments,the check (every day).
7,for instrument and meter,error check (half a year).
Instrument parts:
1,weighing monitor,printer,the appearance of the computer kept clean.
2,often check whether all wiring loose,fracture,ground is firm.
3,keep dry,clean the junction box,box desiccant regular drying replacement.Box if there is water,can use hair dryer drying.
4,instrument in gross state,empty scale,if found zero cursor not bright,weighing should be cleared before.
5,electronic platform balances by legal measure management department regularly check.
6,and off duty,to cut off the weighing of appearance and other electric power.
7,suddenly loses power,instrument need 5 minutes to boot.
8,banned in scale on electric arc welding operation.
9,often cleaning scales a mesa,scale and the bottom around Taiwan gap may not have card of coal stone,foreign body.
10,stop work must be cut off power supply,a mesa long time scale may not stay vehicles or goods.
11,company pounds by the member after the training posts operation.
12,it is strictly prohibited to open weighing display instrument facilities privately,if any problem,please promptly and related supplier technical department contact.
|